Testing & Monitoring — Wide-Area Protection Platform
C-RAS
Centralizes wide-area remedial action scheme (RAS) logic on a high-performance platform — with built-in fault scenario playback, IEC 61850 GOOSE messaging, and AVEVA PI integration for transmission utilities managing constrained corridors.

What C-RAS Delivers
Distributed RAS architectures push protection logic into individual substation devices, making every logic change a device-by-device update and every test cycle slow to execute. C-RAS centralizes that logic on SISCO's Unified Analytic Platform (UAP), giving protection engineers one high-performance environment to develop, test, and deploy wide-area protection schemes.
- High-level RAS development in a Microsoft .NET environment — faster to build, debug, and update than distributed device programs
- Fault scenario playback that replays historical system events directly into RAS algorithms for pre-deployment validation
- GOOSE Blaster-generated multi-device fault simulation for rigorous testing without live substation interaction
- IEC 61850 GOOSE messaging for sub-millisecond inter-substation signaling
- Standards-based device configuration via Substation Configuration Language (SCL) files, supporting multiple manufacturers with no custom integration
- ICCP-TASE.2 (IEC 60870-6) and web service interfaces connecting C-RAS to existing SCADA and EMS environments with no custom middleware
- Deployed on SISCO's Unified Analytic Platform (UAP), which also supports synchrophasor processing for Wide Area Measurement Systems (WAMS)
Technical Specifications
C-RAS runs as an application on SISCO's Unified Analytic Platform (UAP), combining a redundant real-time runtime with historian integration, simulation tooling, and standards-based interfaces for wide-area protection deployment.
- Deployed on SISCO's Unified Analytic Platform (UAP) — high-performance runtime, historian integration, simulation environment, and development toolchain
- IEC 61850 GOOSE messaging for sub-millisecond signaling; Substation Configuration Language (SCL) file-based device configuration
- IEC 60870-6 TASE.2 (ICCP) and web service interfaces for SCADA/EMS integration
- AVEVA PI System integration — system events and application responses historized automatically for fault analysis and performance trending
- C37.118 synchrophasor data stream processing support for Wide Area Measurement Systems (WAMS) applications
- Redundant, real-time runtime architecture for continuous operation
See C-RAS Replace Distributed RAS Logic
SISCO will walk through the development environment, fault playback, and AVEVA PI integration against your use case.